国产一区二区免费在线|国产无遮挡猛进猛出免费软件|中文人妻无码一区二区三区在线|亚洲精品无码mv在线观看网站|未满14周岁啪啪网站|欧美日韩综合一区在线观看

AC source power & DC source power manufacturing factory

Calculating method of alarm current

As we all know, the capacity selection of AC power supply equipment is very important.choosing the right AC power supply is very important for production, manufacturing, testing and R&D!

excessive capacity selection will increase unnecessary property investment; too small capacity selection will affect the normal production, testing and R&D process and even lead to unusable.

therefore, mastering and understanding the calculation of alarm current will clearly know how to choose the capacity of AC power supply equipment. Suitable power supply equipment will make people feel like a tiger!

AC power supply is divided into single-phase power supply and three-phase power supply according to the different output power.therefore, the calculation method of alarm current can also be divided into two kinds: single-phase power supply and three-phase power supply.
the following are introduced separately:

One:Single-phase power supply
Output 0-300V: divided into low and high gear.the alarm current of low-voltage gear is 120 V, and that of high-voltage gear is 240V. capacity (VA)/gear voltage (V)=gear alarm current (A).

Take 5KVA power supply as an example: 5000VA (capacity)/120V (low grade)≈42A; 5000VA/240V (high grade)≈21A.so we get the alarm current: the output of 5KVA power supply is in the range of 0 -150V, the maximum alarm (limit) current is 42A; the output of 5KVA power supply is in the range of 0 -300V, and the maximum alarm (limit) current is 21A.

Output 0-600V, low-grade 240V, high-grade 480V, the same method to get the alarm current of 21/10.5A.
The simple method is that we only need to calculate the low-grade or high-grade alarm current. Another kind of alarm current can be obtained immediately according to the low-grade alarm current = 2 times the high-grade alarm current

Two: Three-phase power supply
The alarm current is a single-phase alarm current, so the three-phase power supply needs capacity/3 to get the single-phase capacity, and then according to the calculation method of the alarm current of the single-phase power supply, the alarm current of the three-phase power supply can be obtained.

Take three-phase 15KVA power supply as an example: 15KVA/3 = 5KVA, 5000VA/120V≈42A (low-grade alarm current), 42A/2 ≈21A (high-grade alarm current).therefore, the alarm current of three-phase 15KVA power supply is 42/21A.

It is not difficult to find that the calculation of alarm current focuses on the unit of capacity is VA, the unit of voltage is V, and the unit of alarm current is A. Therefore, if the known unit of capacity is KVA, the unit of KVA should be converted to VA when calculating the alarm current. 1KVA is 1000VA.
Recommend Products
Online service
Service Hotline
86-769-89616802
86-13602353727

TECHNIC

SERVICES
国产一区二区免费在线|国产无遮挡猛进猛出免费软件|中文人妻无码一区二区三区在线|亚洲精品无码mv在线观看网站|未满14周岁啪啪网站|欧美日韩综合一区在线观看 拉萨市| 枣强县| 四平市| 黎城县| 保山市| 福建省| 鄯善县| 星子县| 武功县| 嘉兴市| 施甸县| 灵石县| 修武县| 山丹县| 农安县| 罗定市| 洛扎县| 崇文区| 漠河县| 兖州市| 平罗县| 介休市| 康平县| 滨海县| 安丘市| 洪湖市| 岳阳市| 中方县| 景洪市| 镇原县| 锦屏县| 钦州市| 宝丰县| 阜阳市| 武川县| 共和县| 惠东县| 金门县| 内丘县| 绿春县| 嘉善县| http://444 http://444 http://444 http://444 http://444 http://444